5102-MCM4-ADM4

Product Description

The ProLinx Modbus Master/Slave to 'C' Programmable Application Development Module creates a powerful platform for developing and running 'C' applications to communicate with Modbus Master/Slave networks and devices. The module provides four serial ports, each individually configurable as a Modbus or custom Master or Slave.

The Modbus (MCM) protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.

Product Applications

The 4102/5102 MCM4-ADM4 module is the ideal solution for many applications where serial connectivity needs to be added to a Modbus Master/Slave platform. Example applications involving the 4102/5102 MCM4-ADM4 module include:
  • Bar code scanner interface
  • Legacy ASCII protocol connections
  • Terminal port emulation
  • Printer driver (alarm/status printer)
  • Customized protocol implementations

Modbus Protocol Specifications

The Modbus driver provides access to an internal database of 4000 registers (words), with extensive support provided for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud Rate, etc).

General Parameters - Modbus Protocol

Type

Specifications

Communication parameters

Baud Rate: 110 to 115K baud

Stop Bits: 1 or 2

Data Size: 7 or 8 bits

Parity: None, Even, Odd

RTS Timing delays: 0 to 65535 ms

Error Checking

RTU mode (binary) with CRC-16
ASCII mode with LRC error checking

Floating Point

Floating point data movement supported, including configurable support for Enron implementation

Function Codes

1 : Read Output Status

2 : Read Input Status

3 : Read Multiple Data Registers

4 : Read Input Registers

5 : Write Single Bit

6 : Write Single Data Register

15 : Write Multiple Bits

16 : Write Multiple Data Register

Modbus Master

Type

Specifications

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

Status Data

Error codes are provided on an individual command basis, as well as a slave status list is maintained per active Modbus Master port.

Polling of command list

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Modbus Slave

Type

Specifications

Node address

1 to 247 - software selectable

Status Data

Error codes, counters and port status available per configured slave port. Status data is all pre-mapped in the module

Hardware Specifications

Click here for dimensions diagram

Certifications

The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class 1, Div 2


Ordering Information

:

5102-MCM4-ADM4

'C' Programmable Modbus Communication Module

To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

Image Gallery



Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested