5201-ADMNET-MCM

Product Description

The ProLinx 'C' Programmable Application Development Module with Ethernet to Modbus Master/Slave creates a powerful platform for developing and running 'C' applications to communicate with Modbus Master/Slave networks and devices. The module provides four serial ports, each individually configurable as a Modbus or custom Master or Slave.

ADMNET Protocol Specifications

The ADM API Suite is provided to allow software developers access to the top layer of the serial ports. The ADMNET API suite accesses the Ethernet port.

Both APIs can be easily used without having detailed knowledge of the module's hardware design. The ADMNET API Suite consists the Ethernet Port API. The Ethernet Port API provides access to the Ethernet network. Applications for the ADMNET module may be developed using industry-standard DOS programming tools and the appropriate API components.

The Modbus (MCM) protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.

Product Applications

The 5201 ADMNET-MCM module is the ideal solution for many applications where Ethernet and serial connectivity need to be added to a Modbus Master/Slave platform. Example applications involving the 5201 ADMNET-MCM module include:
  • Bar code scanner interface
  • Legacy ASCII protocol connections
  • Terminal port emulation
  • Printer driver (alarm/status printer)
  • Customized protocol implementations

Functional Specifications

Internal Database

The ProLinx module contains an internal database that can be configured as needed to handle your data transfer.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

General Protocol Specifications

  • Allows software developers to access Serial/Ethernet ports without needing detailed knowledge of the module's hardware design
  • API library functions are specified using the C programming language syntax
  • Supports multi-threaded applications
  • The following compiler versions are compatible with the MVI module API:
    • DigitalMars C++ V8.49
    • Borland C++ V5.02
  • Operating System - General software DOS 6-XL
  • Flash ROM program space: 896 KB
  • RAM program and data space: 640 KB
  • Compact Flash socket: Up to 64 MB

ADM API Libraries

Each API provides a library of function calls. This library supports any programming language that is compatible with the Pascal calling convention.

  • Initialization - Open and close the API
  • Debug Port - Debug port user interface
  • Database - Read and write data to database
  • Timer - Start and check timers
  • Backplane - Transfer data over the backplane
  • LED - Set user LED indicators
  • Flash - Parse configuration files
  • Miscellaneous - Configure the console

Modbus Protocol Specifications

The Modbus driver provides access to an internal database of 4000 registers (words), with extensive support provided for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud Rate, etc).

General Parameters - Modbus Protocol

Type

Specifications

Communication parameters

Baud Rate: 110 to 115K baud

Stop Bits: 1 or 2

Data Size: 7 or 8 bits

Parity: None, Even, Odd

RTS Timing delays: 0 to 65535 ms

Error Checking

RTU mode (binary) with CRC-16
ASCII mode with LRC error checking

Floating Point

Floating point data movement supported, including configurable support for Enron implementation

Function Codes

1 : Read Output Status

2 : Read Input Status

3 : Read Multiple Data Registers

4 : Read Input Registers

5 : Write Single Bit

6 : Write Single Data Register

15 : Write Multiple Bits

16 : Write Multiple Data Register

Modbus Master

Type

Specifications

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

Status Data

Error codes are provided on an individual command basis, as well as a slave status list is maintained per active Modbus Master port.

Polling of command list

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Modbus Slave

Type

Specifications

Node address

1 to 247 - software selectable

Status Data

Error codes, counters and port status available per configured slave port. Status data is all pre-mapped in the module

Hardware Specifications

Click here for dimensions diagram

Certifications

The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class 1, Div 2


Ordering Information

5201-ADMNET-MCM

'C' Programmable with Ethernet Modbus Communication Module

To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

Image Gallery


Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested